Order guide
GX-6 type
Type | Appearance (mm in) |
Sensing range (Note 1) |
Model No. (Note 2) |
Output | Output operation | |
---|---|---|---|---|---|---|
NPN output |
Front sensing |
Maximum operation distance: 1.6 mm 0.063 in Stable sensing range : 0 to 1.3 mm 0 to 0.051 in |
GX-F6A | NPN open-collector transistor |
Normally open | |
GX-F6AI | ||||||
GX-F6B | Normally closed | |||||
GX-F6BI | ||||||
Top sensing |
GX-H6A | Normally open | ||||
GX-H6AI | ||||||
GX-H6B | Normally closed | |||||
GX-H6BI | ||||||
PNP output |
Front sensing |
GX-F6A-P | PNP open-collector transistor |
Normally open | ||
GX-F6AI-P | ||||||
GX-F6B-P | Normally closed | |||||
GX-F6BI-P | ||||||
Top sensing |
GX-H6A-P | Normally open | ||||
GX-H6AI-P | ||||||
GX-H6B-P | Normally closed | |||||
GX-H6BI-P |
Note 1 : | The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
---|---|
Note 2 : | ” I ” in the model No. indicates a different frequency type. |
GX-8 type
Type | Appearance (mm in) |
Sensing range (Note 1) |
Model No. (Note 2) |
Output | Output operation | |
---|---|---|---|---|---|---|
NPN output |
Front sensing |
Maximum operation distance: 2.5 mm 0.098 in Stable sensing range : 0 to 2.1 mm 0 to 0.083 in |
GX-F8A | NPN open-collector transistor |
Normally open | |
GX-F8AI | ||||||
GX-F8B | Normally closed | |||||
GX-F8BI | ||||||
Top sensing |
GX-H8A | Normally open | ||||
GX-H8AI | ||||||
GX-H8B | Normally closed | |||||
GX-H8BI | ||||||
PNP output |
Front sensing |
GX-F8A-P | PNP open-collector transistor |
Normally open | ||
GX-F8AI-P | ||||||
GX-F8B-P | Normally closed | |||||
GX-F8BI-P | ||||||
Top sensing |
GX-H8A-P | Normally open | ||||
GX-H8AI-P | ||||||
GX-H8B-P | Normally closed | |||||
GX-H8BI-P |
Note 1 : | The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
---|---|
Note 2 : | ” I ” in the model No. indicates a different frequency type. |
GX-12 type
Type | Appearance (mm in) |
Sensing range (Note 1) |
Model No. (Note 2) |
Output | Output operation | |
---|---|---|---|---|---|---|
NPN output |
Front sensing |
Maximum operation distance: 4.0 mm 0.157 in Stable sensing range : 0 to 3.3 mm 0 to 0.130 in |
GX-F12A | NPN open-collector transistor |
Normally open | |
GX-F12AI | ||||||
GX-F12B | Normally closed | |||||
GX-F12BI | ||||||
Top sensing |
GX-H12A | Normally open | ||||
GX-H12AI | ||||||
GX-H12B | Normally closed | |||||
GX-H12BI | ||||||
PNP output |
Front sensing |
GX-F12A-P | PNP open-collector transistor |
Normally open | ||
GX-F12AI-P | ||||||
GX-F12B-P | Normally closed | |||||
GX-F12BI-P | ||||||
Top sensing |
GX-H12A-P | Normally open | ||||
GX-H12AI-P | ||||||
GX-H12B-P | Normally closed | |||||
GX-H12BI-P |
Note 1 : | The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
---|---|
Note 2 : | ” I ” in the model No. indicates a different frequency type. |
GX-15 type
Type | Appearance (mm in) |
Sensing range (Note 1) |
Model No. (Note 2) |
Output | Output operation | |
---|---|---|---|---|---|---|
NPN output |
Front sensing |
Maximum operation distance: 5.0 mm 0.197 in Stable sensing range : 0 to 4.2 mm 0 to 0.165 in |
GX-F15A | NPN open-collector transistor |
Normally open | |
GX-F15AI | ||||||
GX-F15B | Normally closed | |||||
GX-F15BI | ||||||
Top sensing |
GX-H15A | Normally open | ||||
GX-H15AI | ||||||
GX-H15B | Normally closed | |||||
GX-H15BI | ||||||
PNP output |
Front sensing |
GX-F15A-P | PNP open-collector transistor |
Normally open | ||
GX-F15AI-P | ||||||
GX-F15B-P | Normally closed | |||||
GX-F15BI-P | ||||||
Top sensing |
GX-H15A-P | Normally open | ||||
GX-H15AI-P | ||||||
GX-H15B-P | Normally closed | |||||
GX-H15BI-P |
Note 1 : | The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
---|---|
Note 2 : | ” I ” in the model No. indicates a different frequency type. |
GX-15 ( Long sensing range ) type
Type | Appearance (mm in) |
Sensing range (Note 1) |
Model No. (Note 2) |
Output | Output operation | |
---|---|---|---|---|---|---|
NPN output |
Front sensing |
Maximum operation distance: 8.0 mm 0.315 in Stable sensing range : 0 to 6.7 mm 0 to 0.264 in |
GX-FL15A | NPN open-collector transistor |
Normally open | |
GX-FL15AI | ||||||
GX-FL15B | Normally closed | |||||
GX-FL15BI | ||||||
Top sensing |
GX-HL15A | Normally open | ||||
GX-HL15AI | ||||||
GX-HL15B | Normally closed | |||||
GX-HL15BI | ||||||
PNP output |
Front sensing |
GX-FL15A-P | PNP open-collector transistor |
Normally open | ||
GX-FL15AI-P | ||||||
GX-FL15B-P | Normally closed | |||||
GX-FL15BI-P | ||||||
Top sensing |
GX-HL15A-P | Normally open | ||||
GX-HL15AI-P | ||||||
GX-HL15B-P | Normally closed | |||||
GX-HL15BI-P |
Note 1 : | The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object. The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient temperature drift and/or supply voltage fluctuation. |
---|---|
Note 2 : | ” I ” in the model No. indicates a different frequency type. |
5 m 16.404 ft cable length type, bending-resistant cable type
5 m 16.404 ft cable length type (standard: 1 m 3.281 ft) and bending-resistant cable (excluding 5 m 16.404 ft cable length type) are available.
However, long sensing range type is not available. When ordering 5 m 16.404 ft cable length type, suffix “-C5” to the model No. When ordering bending-resistant cable type, suffix “-R” to the model No.
(e.g.) 5 m 16.404 ft cable length type of GX-F15AI-P is “GX-F15AI-P-C5”. Bending-resistant cable type of GX-F15AI-P is “GX-F15AI-P-R”.
・List of model No.