Order guide
PRODUCT CONFIGURATION
|
[1]. Safety Light curtains
Mounting bracket and bottom cap cable are not supplied with the safety light curtain. Be sure to order them separately. |
Hand protection type
Min. sensing object ø27 mm ø1.063 in (20 mm 0.787 in beam pitch)
Appearance | Operating range (Note 1) |
Model No. (Note 4) |
Number of beam channels |
Protective height (mm in) |
|
---|---|---|---|---|---|
NPN output type | PNP output type | ||||
0.2 to 13 m 0.656 to 42.651 ft [When using the adapter cable SF2B-CB05-B:0.2 to 5 m 0.656 to 16.404 ft] |
SF2B-H8-N (Note 2) |
SF2B-H8-P (Note 2) |
8 | 168 6.614 | |
SF2B-H12-N | SF2B-H12-P | 12 | 232 9.134 | ||
SF2B-H16-N | SF2B-H16-P | 16 | 312 12.283 | ||
SF2B-H20-N | SF2B-H20-P | 20 | 392 15.433 | ||
SF2B-H24-N | SF2B-H24-P | 24 | 472 18.583 | ||
SF2B-H28-N | SF2B-H28-P | 28 | 552 21.732 | ||
SF2B-H32-N | SF2B-H32-P | 32 | 632 24.882 | ||
SF2B-H36-N | SF2B-H36-P | 36 | 712 28.031 | ||
SF2B-H40-N | SF2B-H40-P | 40 | 792 31.181 | ||
SF2B-H48-N | SF2B-H48-P | 48 | 952 37.480 | ||
SF2B-H56-N | SF2B-H56-P | 56 | 1,112 43.779 | ||
SF2B-H64-N | SF2B-H64-P | 64 | 1,272 50.079 | ||
SF2B-H72-N | SF2B-H72-P | 72 | 1,432 56.378 | ||
SF2B-H80-N | SF2B-H80-P | 80 | 1,592 62.677 | ||
SF2B-H88-N | SF2B-H88-P | 88 | 1,752 68.976 | ||
SF2B-H96-N | SF2B-H96-P | 96 | 1,912 75.275 |
Arm / Foot protection type
Min. sensing object ø47 mm ø1.850 in (40 mm 1.575 in beam pitch)
Appearance | Operating range (Note 1) |
Model No. (Note 4) |
Number of beam channels |
Protective height (mm in) |
|
---|---|---|---|---|---|
NPN output type | PNP output type | ||||
0.2 to 13 m 0.656 to 42.651 ft [When using the adapter cable SF2B-CB05-B:0.2 to 5 m 0.656 to 16.404 ft] |
SF2B-A4-N (Note 2) |
SF2B-A4-P (Note 2) |
4 | 168 6.614 | |
SF2B-A6-N | SF2B-A6-P | 6 | 232 9.134 | ||
SF2B-A8-N | SF2B-A8-P | 8 | 312 12.283 | ||
SF2B-A10-N | SF2B-A10-P | 10 | 392 15.433 | ||
SF2B-A12-N | SF2B-A12-P | 12 | 472 18.583 | ||
SF2B-A14-N | SF2B-A14-P | 14 | 552 21.732 | ||
SF2B-A16-N | SF2B-A16-P | 16 | 632 24.882 | ||
SF2B-A18-N | SF2B-A18-P | 18 | 712 28.031 | ||
SF2B-A20-N | SF2B-A20-P | 20 | 792 31.181 | ||
SF2B-A24-N | SF2B-A24-P | 24 | 952 37.480 | ||
SF2B-A28-N | SF2B-A28-P | 28 | 1,112 43.779 | ||
SF2B-A32-N | SF2B-A32-P | 32 | 1,272 50.079 | ||
SF2B-A36-N | SF2B-A36-P | 36 | 1,432 56.378 | ||
SF2B-A40-N | SF2B-A40-P | 40 | 1,592 62.677 | ||
SF2B-A44-N | SF2B-A44-P | 44 | 1,752 68.976 | ||
SF2B-A48-N | SF2B-A48-P | 48 | 1,912 75.275 |
Note:
1) | The “operating range” is the possible setting distance between the emitter and the receiver. |
---|---|
2) | The SF2B-H8-□ and SF2B-A4-□ cannot be connected in series because they do not include a connector for series connection. |
3) | The distance between the tip of the safety light curtain and the last beam axis of the SF2B-H8-□ and SF2B-A4-□ is 22 mm 0.866 in. |
4) | Models which have an “E” symbol in the model No. on the name plate are emitters, and those with a “D” symbol are receivers. |
[2]. Mounting brackets
Mounting bracket is not supplied with the safety light curtain. Be sure to order it separately. |
Designation | Appearance | Model No. | Description | ||
---|---|---|---|---|---|
Standard mounting bracket |
MS-SF2B-1 | Used to mount the safety light curtain on the rear surface and side surface (4 pcs. per set for emitter and receiver) |
|||
Dead zoneless mounting bracket |
MS-SF2B-3 | Mounting of the safety light curtain is possible so that the mounting bracket does not project past the protective height (safety light curtain length). (4 pcs. per set for emitter and receiver) |
|||
Adapter mounting brackets |
For SF2-A / SF2-N |
For rear and side mounting |
MS-SF2B-5 | Used when replacing units in the SF2-A / SF2-N series.(discontinude mode) (4 pcs. per set for emitter and receiver) |
|
For SF1-N / NA40 |
For rear mounting |
MS-SF2B-4 | Used when replacing units in the SF1-N(discontinude mode) / NA40 series which are using the MS-SF1-1 / MS-NA40-1 sensor mounting brackets.(Note) (4 pcs. per set for emitter and receiver) |
||
For NA40 |
For side mounting |
MS-SF2B-6 | Used when replacing units in the NA40 series which are side mounted (direct mounted).(Note) (4 pcs. per set for emitter and receiver) |
||
For SF1-N |
For side mounting |
MS-SF2B-7 | Used when replacing units in the SF1-N series (discontinude mode) which are side mounted (discontinude mode) . (4 pcs. per set for emitter and receiver) |
Note: | SF1-N-compatible mounting bracket can also be used for SF1-S / SF1-A series products that are discontinued. The NA40-compatible mounting bracket can also be used for NA40-S / NA40-B series products that are discontinued. |
---|
Standard mounting bracket
|
|
|
|
|
|
[3]. [4]. [5]. Mating cable / Extension cable / Cables for series connection
Mating cable is not supplied with the safety light curtain. Be sure to order it separately. |
[3]Bottom cap cable
Type | Appearance | Model No. | Description | |||
---|---|---|---|---|---|---|
8-core cable |
Discrete wire |
SF2B-CCB3 | Cable length: 3 m 9.843 ft Net weight: 370 g approx. (2 cables) |
Used for connecting to the safety light curtain and to other cables or the SF-C13 control unit. Two cables per set for emitter and receiver Cable outer diameter: ø6 mm ø0.236 in Cable color: Gray (for emitter) Gray with black line (for receiver) The min. bending radius: R6 mm R0.236 in |
||
SF2B-CCB7 | Cable length: 7 m 22.966 ft Net weight: 820 g approx. (2 cables) |
|||||
SF2B-CCB10 | Cable length: 10 m 32.808 ft Net weight: 1,160 g approx. (2 cables) |
|||||
SF2B-CCB15 | Cable length: 15 m 49.213 ft Net weight: 1,720 g approx. (2 cables) |
|||||
Connector | SF2B-CB05 | Cable length: 0.5 m 1.640 ft Net weight: 95 g approx. (2 cables) |
Used for connecting to the safety light curtain and to an extension cable or the SF-C11 control unit. Two cables per set for emitter and receiver Cable outer diameter: ø6 mm ø0.236 in Connector outer diameter: ø14 mm ø0.551 inmax. Cable color: Gray (for emitter), Gray with black line (for receiver) Connector color: Gray (for emitter), Black (for receiver) The min. bending radius: R6 mm R0.236 in |
|||
SF2B-CB5 | Cable length: 5 m 16.404 ft Net weight: 620 g approx. (2 cables) |
|||||
SF2B-CB10 | Cable length: 10 m 32.808 ft Net weight: 1,200 g approx. (2 cables) |
[4]Extension cable
Type | Appearance | Model No. | Description | |||
---|---|---|---|---|---|---|
8-core cable |
Discrete wire |
SFB-CC3 | Cable length: 3 m 9.843 ft Net weight: 380 g approx. (2 cables) |
Used for cable extension or connecting to the SF-C13 control unit. Two cables per set for emitter and receiver Cable outer diameter: ø6 mm ø0.236 in Connector outer diameter: ø14 mm ø0.551 in max. Cable color: Gray (for emitter), Gray with black line (for receiver) The min. bending radius: R6 mm R0.236 in |
||
SFB-CC10 | Cable length: 10 m 32.808 ft Net weight: 1,200 g approx. (2 cables) |
|||||
With connectors on both ends |
For emitter |
SFB-CCJ10E | Cable length: 10 m 32.808 ft Net weight: 580 g approx. (1 cable) |
Used for cable extension or connecting to the SF-C11 control unit. One each for emitter and receiver Cable outer diameter: ø6 mm ø0.236 in Connector outer diameter: ø14 mm ø0.551 in max. Cable color: Gray (for emitter), Gray with black line (for receiver) Connector color: Gray (for emitter), Black (for receiver) The min. bending radius: R6 mm R0.236 in |
||
For receiver |
SFB-CCJ10D | Cable length: 10 m 32.808 ft Net weight: 600 g approx. (1 cable) |
[5]Cable for series connection
Appearance | Model No. | Description | |
---|---|---|---|
* Used in conjunction with sub-sensor for serial connection only. |
SF2B-CSL01 | Cable length: 0.1 m 0.328 ft Net weight: 70 g approx. (2 cables) |
Use when connecting the sub-sensor for series connection to the safety light curtain in series. Two cables per set for emitter and receiver (common for emitter and receiver) Cable outer diameter: ø6 mm ø0.236 in Cable color: Gray (common for emitter and receiver) The min. bending radius: R6 mm R0.236 in |
SF2B-CSL05 | Cable length: 0.5 m 1.640 ft Net weight: 120 g approx. (2 cables) |
*[3]Adapter cable (Bottom cap cable)
Type | Appearance | Model No. | Description | |||
---|---|---|---|---|---|---|
8-core cable |
For SF2-A / SF2-N |
* Please contact our office for wiring of adapter cables. |
SF2B-CB05-A | Cable length: 0.5 m 1.640 ft Net weight: 95 g approx. (2 cables) |
Used when replacing units in the SF2-A / SF2-N series(discontinude mode). The SF2N-CC□ cable with connector can be used without change, so that replacement with SF2B series units can be done smoothly. Two cables per set for emitter and receiver Cable outer diameter: ø6 mm ø0.236 in Connector outer diameter: ø14 mm ø0.551 in max. Cable color: Gray (for emitter), Gray with black line (for receiver) Connector color: Gray (for emitter), Black (for receiver) The min. bending radius: R6 mm R0.236 in |
|
4-core cable |
For SF1‑N / NA40 |
SF2B-CB05-B | Cable length: 0.5 m 1.640 ft Net weight: 95 g approx. (2 cables) |
Used when replacing units in the SF1-N(discontinude mode) / NA40 series. The SF1-CC□ / NA40-CC□ cable with connector can be used without change, so that replacement with SF2B series units can be done smoothly. Two cables per set for emitter and receiver Cable outer diameter: ø6 mm ø0.236 in Connector outer diameter: ø14 mm ø0.551 in max. Cable color: Gray (for emitter), Gray with black line (for receiver) Connector color: Gray (for emitter), Black (for receiver) The min. bending radius: R6 mm R0.236 in |
*Interchangeability function
This function is used for replacing other safety light curtains or area sensors with these new units. The bottom cap cables and sensor mounting brackets used will vary depending on the models being replaced. Refer to the instruction manual for details on actual wiring and mounting.
Models being replaced | Adapter cable | Adapter mounting bracket | Details of changes and points to note |
---|---|---|---|
SF2-A / SF2-N series (Discontinued product) |
SF2B-CB05-A | MS-SF2B-5 | ・NPN output type: Connect the shielded wire to +V. PNP output type: Connect the shielded wire to 0 V. ・Existing SF2N-CC□ connection cables (optional) can be used without change. ・The interference prevention function (parallel connection) cannot be used. |
SF1-N series (Discontinued product) |
SF2B-CB05-B | When using the MS-SF1-1:MS-SF2B-4 For direct mounting: MS-SF2B-7 |
・Emitter: Synchronization cable has changed to interference prevention cable.(Note 1) Receiver: Synchronization cable has changed to control output (OSSD 1).(Note 2)(Note 3) ・Existing SF1-CC□A connection cables (optional) can be used without change. ・The beam axis alignment indicator of emitter cannot be used. |
NA40 series | SF2B-CB05-B | When using the MS-NA40-1:MS-SF2B-4 For direct mounting: MS-SF2B-6 |
・Control output (OSSD 2) is equipped instead of self-diagnosis output.(Note 3) ・Emission halt function cannot be used. ・Existing NA40-CC□ connection cables (optional) can be used without change. ・The ambient temperature for the NA40-CC□ connection cables (optional) is –10 to +50 ℃ +14 to +122 ℉. |
Notes:
1) | Not used in case of simple replacement of the SF1-N series (interference prevention wire is unused), therefore perform wire insulation so that it will not touch other wires. |
---|---|
2) | Not used in case of simple replacement of the SF1-N series (non-safety applications), therefore perform wire insulation so that it will not touch other wires. |
3) | When used in safety applications, both OSSD1 and OSSD2 must be used. |
[6]. Sub-sensor for series connection only
The sub-sensors for series connection are PNP / NPN types. Furthermore, they cannot simply be used by themselves. Always be sure to use them in combination with safety light curtains. |
Hand protection type
Min. sensing object ø27 mm ø1.063 in (20 mm 0.787 in beam pitch)
Appearance | Operating range (Note 1) |
Model No. (Note 5) |
Number of beam channels |
Protective height (mm in) |
Current consumption (Note 4) |
---|---|---|---|---|---|
0.2 to 13 m 0.656 to 42.651 ft [When using SF2B-CB05-B adapter cable at safety light curtain:0.2 to 5 m 0.656 to 16.404 ft] |
SF2B-H8SL (Note 2) |
8 | 168 6.614 | Emitter: 20 mA or less Receiver: 25 mA or less |
|
SF2B-H12SL | 12 | 232 9.134 | |||
SF2B-H16SL | 16 | 312 12.283 | Emitter: 20 mA or less Receiver: 35 mA or less |
||
SF2B-H20SL | 20 | 392 15.433 | |||
SF2B-H24SL | 24 | 472 18.583 | Emitter: 30 mA or less Receiver: 45 mA or less |
||
SF2B-H28SL | 28 | 552 21.732 | |||
SF2B-H32SL | 32 | 632 24.882 | Emitter: 30 mA or less Receiver: 55 mA or less |
||
SF2B-H36SL | 36 | 712 28.031 | |||
SF2B-H40SL | 40 | 792 31.181 | Emitter: 40 mA or less Receiver: 65 mA or less |
||
SF2B-H48SL | 48 | 952 37.480 | |||
SF2B-H56SL | 56 | 1,112 43.779 | Emitter: 45 mA or less Receiver: 85 mA or less |
||
SF2B-H64SL | 64 | 1,272 50.079 | |||
SF2B-H72SL | 72 | 1,432 56.378 | Emitter: 50 mA or less Receiver: 105 mA or less |
||
SF2B-H80SL | 80 | 1,592 62.677 | |||
SF2B-H88SL | 88 | 1,752 68.976 | Emitter: 60 mA or less Receiver: 125 mA or less |
||
SF2B-H96SL | 96 | 1,912 75.275 |
Arm / Foot protection type
Min. sensing object ø47 mm ø1.850 in (40 mm 1.575 in beam pitch)
Appearance | Operating range (Note 1) |
Model No. (Note 6) |
Number of beam channels |
Protective height (mm in) |
Current consumption (Note 4) |
---|---|---|---|---|---|
0.2 to 13 m 0.656 to 42.651 ft [When using SF2B-CB05-B adapter cable at safety light curtain:0.2 to 5 m 0.656 to 16.404 ft] |
SF2B-A4SL (Note 2) |
4 | 168 6.614 | Emitter: 15 mA or less Receiver: 20 mA or less |
|
SF2B-A6SL | 6 | 232 9.134 | |||
SF2B-A8SL | 8 | 312 12.283 | Emitter: 15 mA or less Receiver: 25 mA or less |
||
SF2B-A10SL | 10 | 392 15.433 | |||
SF2B-A12SL | 12 | 472 18.583 | Emitter: 20 mA or less Receiver: 30 mA or less |
||
SF2B-A14SL | 14 | 552 21.732 | |||
SF2B-A16SL | 16 | 632 24.882 | Emitter: 20 mA or less Receiver: 35 mA or less |
||
SF2B-A18SL | 18 | 712 28.031 | |||
SF2B-A20SL | 20 | 792 31.181 | Emitter: 25 mA or less Receiver: 40 mA or less |
||
SF2B-A24SL | 24 | 952 37.480 | |||
SF2B-A28SL | 28 | 1,112 43.779 | Emitter: 25 mA or less Receiver: 50 mA or less |
||
SF2B-A32SL | 32 | 1,272 50.079 | |||
SF2B-A36SL | 36 | 1,432 56.378 | Emitter: 30 mA or less Receiver: 60 mA or less |
||
SF2B-A40SL | 40 | 1,592 62.677 | |||
SF2B-A44SL | 44 | 1,752 68.976 | Emitter: 35 mA or less Receiver: 70 mA or less |
||
SF2B-A48SL | 48 | 1,912 75.275 |
Note:
1) | The “operating range” is the possible setting distance between the emitter and the receiver. |
---|---|
2) | The SF2B-H8SL and SF2B-A4SL do not include a connector for series connection. Therefore, when connecting 3 sets in series, the sub-sensor can be used only for the third set. |
3) | The distance between the tip of the safety light curtain and the top beam axis of the SF2B-H8SL and SF2B-A4SL is 22 mm 0.866 in. |
4) | The specifications of the sub-sensor for series connection are the same as for the safety light curtain, except for the current consumption. However, the sub-sensor is not equipped with an output. |
5) | Models which have an “E” symbol in the model No. on the name plate are emitters, and those with a “D” symbol are receivers. |
Spare parts (Accessories for safety light curtain)
Designation | Appearance | Model No. | Description |
---|---|---|---|
Intermediate supporting bracket (Note) |
MS-SF2B-2 | Used to mount the safety light curtain on the intermediate position. Mounting is possible behind or at the side of the safety light curtain. | |
Test rod φ27 | SF2B-TR27 | Min. sensing object for regular checking (φ27 mm φ1.063 in), with hand protection type (min. sensing object φ27 mm φ1.063 in) |
Note: | Depending on the product, the required set number will vary as follows. 1 set: SF2B-H□・・・Safety Light curtain with 40 to 56 beam channels, SF2B-A□・・・Safety Light curtain with 20 to 28 beam channels 2 sets: SF2B-H□・・・Safety Light curtain with 64 to 80 beam channels, SF2B-A□・・・Safety Light curtain with 32 to 40 beam channels 3 sets: SF2B-H□・・・Safety Light curtain with 88 to 96 beam channels, SF2B-A□・・・Safety Light curtain with 44 to 48 beam channels |
---|
Intermediate supporting bracket
MS-SF2B-2
|
|
Hãy là người đầu tiên nhận xét “Safety Light Curtain Type 2 SF2B (Panasonic)”